How To Program Caddx Nx 8v2

Posted on by
How To Program Caddx Nx 8v2 Rating: 6,8/10 5588votes
How To Program Caddx Nx 8v2

Need Help Integrating NX-8V2 Panel. I am new to the forum, and am struggling with getting an NX-8V2/NX-584 integrated with my VeraLite using the Caddx app. When I took a stab at this several months. Linux Ubuntu Transformation Pack For Windows 7. I figured out the location mapping, by reading the manual again, that's my bad. However, I am. NX 8V2 Control Board GE Caddx Keypad 0 results. GE Caddx NetworX NX-8 V2. GE NX-148E ALPHA PROGRAM LCD DISPLAY KEYPAD PROGRAMMING ALARM INTERLOGIX CADDX U. When you exit program mode, the NX-8V2 automatically. NX-8V2-Control Panel Installation Instructions.,,. Silent Hunter 3 Скачать На Русском. The NX-8 has a 185-event log that. This is the NX-8V2-Control Panel Installation Instructions. Installations should only. NetworX keypad maximum wire run. Table 1 below lists. The wire, a higher gauge wire is required. Table 1: Maximum keypad wire run. Length in feet. Wire gauge for NX. Wire gauge for NX320.

UNDERSTANDING THE LIGHTS Light Status/Note Description System is armed System is disarmed There has been an alarm during the previous arm cycle A zone/some zones the keypad's partition is/are bypassed No zones are bypassed System is on abort delay time Code is entered followed by the [ CANCEL ] key during or after an alarm report to the central station Note It stays on until the central station has received the cancel report Note The cancel feature must be enabled. Chime feature is on Chime feature is off System is on exit delay System is on exit delay, user has 10 seconds to exit Note The user may want to disarm the system if the exit light is still flashing in order to prevent an alarm Note The user may then re-arm the system and exit before the delay expires A fire zone has been faulted A fire zone is in a trouble condition Primary power is on System has a low battery System is ready to arm System is ready to force arm System is not ready to arm because of a zone/some zones is/are being faulted All interior zones are bypassed. MAKING THE SYSTEM READY TO ARM If the ready light is not on or if it is flashing then at least one zone is not secure To identify the zones, use the scroll keys ( or ) to the right of the display to browse through the zones that are not secure If the user wishes to bypass or unbypass one of these zones, press the key while that zone is being displayed When finished viewing the zones, press the key to return to the code entry screen ARMING THE SYSTEM IN THE 'STAY' MODE STAY is utilized when the user is inside the premise and wants protection around the perimeter. Step 1 Close all protected doors and windows Ready light will be on or flashing when all protected zones and sensors are secure. NOTE: If any zones are bypassed, a sensor in that zone can be violated without affecting the ready light. The security system will not arm if the ready light is not on or flashing. If the power light is off, there is no AC power.

Contact a technician. System Ready Type Code to Arm Step 2 Enter 4 or 6 digit user code. (Optional; if programmed.) If 'Auto Bypass' is enabled, all interior zones will be bypassed if the user do not leave through a designated entry/exit door. If Auto Bypass is enabled, omit Step 3. When ' Auto Instant' is enabled, if you do not leave through a designated entry/exit door, the display will read 'Instant', indicating that the entry /exit doors no longer have an entry delay. If 'Auto Instant' is enabled, omit Step 4.

Business Environment In A Global Context Pdf Free. Step 3 Press the key. The stay light will illuminate indicating that all interior zones are bypassed. (All interior devices will bypass automatically, giving the user freedom of movement within the interior area.) The bypass light will illuminate if any zone(s) are bypassed.

If any zone(s) have been bypassed previously by the user, the light(s) corresponding to the bypassed zone(s) will illuminate, alerting the user that a zone(s) may be unprotected and can be faulted without an alarm. Step 4 To toggle from a 'delayed entry' mode to an 'Instant' mode, press key again. The instant light will illuminate indicating that the entry/exit doors have no entry delay. CANCEL/ABORT FEATURE The cancel light will flash during an abort delay time If a code is entered followed by the key while this light is flashing, all abortable reports will stop the communication process. NOTE: The abort feature must be enabled for this feature to be functional. This feature is for arming ONLY Entering a code followed by the key during or after an alarm report to the central station will cause the cancel light to come on It will stay on until the central station has received the cancel report.

NOTE: The cancel feature must be enabled for this feature to be functional BYPASSING ZONES If the user wishes to bypass one or more zones, this must be done while the system is in the disarmed state NOTE: If the user knows the number of zones, use; use otherwise. Zone Bypass Procedure 1 Step 1 Press the key Step 2 Enter the user code, if required (optional). The bypass light flashes. Step 3 Enter 1 or 2 digits indicating the zone the user wishes to bypass. (Example: Press the key for zone 1 or keys for zone 12.) Step 4 Press the key again. Step 5 The corresponding zone light will illuminate indicating the zone has been bypassed. Repeat steps 3 and 4 for any other zone(s) that need to be bypassed.

Comments are closed.